𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A respiratory self-gating technique with 3D-translation compensation for free-breathing whole-heart coronary MRA

✍ Scribed by Peng Lai; Xiaoming Bi; Renate Jerecic; Debiao Li


Book ID
102953130
Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
524 KB
Volume
62
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Respiratory motion remains a major challenge for robust coronary MR angiography (MRA). Diaphragmatic navigator (NAV) suffers from indirect measurement of heart position. Respiratory self‐gating (RSG) approaches improve motion detection only in the head–feet direction, leaving motion in the other two dimensions unaccounted for. The purpose of this study was to extend conventional RSG (1D RSG) to RSG capable of 3D motion detection (3D RSG) by acquiring additional RSG projections with transverse‐motion‐encoding gradients. Simulation and volunteer studies were conducted to validate the effectiveness of this new method. Preliminary comparison was performed between coronary artery images reconstructed from the same datasets using different motion correction methods. Our simulation illustrates that a proper motion‐encoding gradient and derivation method enable accurate 3D motion detection. Results from whole‐heart coronary MRA show that 3D RSG can further reduce motion artifacts as compared to NAV and 1D RSG and enables use of larger gating windows for faster coronary imaging. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


A dual-projection respiratory self-gatin
✍ Peng Lai; Andrew C. Larson; Xiaoming Bi; Renate Jerecic; Debiao Li 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 532 KB

## Abstract ## Purpose To investigate the accuracy of a dual‐projection respiratory self‐gating (DP‐RSG) technique in dynamic heart position measurement and its feasibility for free‐breathing whole‐heart coronary MR angiography (MRA). ## Materials and Methods A DP‐RSG method is proposed to enabl

Free-breathing whole-heart coronary MRA
✍ C. Stehning; P. Börnert; K. Nehrke; H. Eggers; M. Stuber 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 305 KB

## Abstract Respiratory motion is a major source of artifacts in cardiac magnetic resonance imaging (MRI). Free‐breathing techniques with pencil‐beam navigators efficiently suppress respiratory motion and minimize the need for patient cooperation. However, the correlation between the measured navig

Self-guided retrospective motion correct
✍ Jianing Pang; Himanshu Bhat; Behzad Sharif; Zhaoyang Fan; Edward B Gill; James M 📂 Article 📅 2012 🏛 BioMed Central 🌐 English ⚖ 207 KB

A respiratory motion correction method (SEGMO) is proposed for whole-heart coronary MRA. It eliminates the need for a diaphragm navigator, reduces imaging setup time, and has more accurate respiratory motion detection using an affine model. Its inherent 100% gating efficiency ensures a shorter and m