𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A reproducible method for damage-free site-specific preparation of atom probe tips from interfaces

✍ Scribed by Peter Johann Felfer; Talukder Alam; Simon Peter Ringer; Julie Marie Cairney


Book ID
102890535
Publisher
John Wiley and Sons
Year
2011
Tongue
English
Weight
589 KB
Volume
75
Category
Article
ISSN
1059-910X

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Atom probe tomography (APT) is a mass spectrometry method with atomic‐scale spatial resolution that can be used for the investigation of a wide range of materials. The main limiting factor with respect to the type of problems that can be addressed is the small volume investigated and the randomness of common sample preparation methods. With existing site‐specific specimen preparation methods it is still challenging to rapidly and reproducibly produce large numbers of successful samples from specifically selected grain boundaries or interfaces for systematic studies. A new method utilizing both focused ion beam (FIB) and transmission electron microscopy (TEM) is presented that can be used to reproducibly produce damage‐free atom probe samples with features of interest at any desired orientation with an accuracy of better than 50 nm from samples that require very little prior preparation. Microsc. Res. Tech. 2011. © 2011 Wiley‐Liss, Inc.