𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A precipitation sampler intercomparison

✍ Scribed by Walter H. Chan; Maris A. Lusis; R. D. Samuel Stevens; Robert J. Vet


Book ID
104655116
Publisher
Springer Netherlands
Year
1984
Tongue
English
Weight
664 KB
Volume
23
Category
Article
ISSN
0049-6979

No coin nor oath required. For personal study only.

✦ Synopsis


A three month experimental study to evaluate the relative performance of three different designs of 'event' precipitation chemistry samplers was carried out at Woodbridge, Ontario beginning in August 1979. The samplers evaluated were an automatic Aerochem Metrics, 'wet-only' type (A), a funnel-and-bottle type (F), and a large-mouth plastic bucket with a specially-fabricated polyethylene bag insert (S). Each sampler was run in duplicate, with a sampling period of 24 hr.

The results show that at sites where dry deposition is important, bulk samplers ('F' and 'S' types) yield significantly different results from the wet-only collector including rainfall amount, H +, SO 4-, NO 3 , Na +, K+, Ca + +, and Mg + +. However, the bulk samplers, especially the 'S' type, are found to be satisfactory under certain conditions. For conditions which correspond to daily rainfall less than 2.8 mm and windier and drier sampling, there is even evidence of dry contamination of the wet-only type sampler.


πŸ“œ SIMILAR VOLUMES


Atmospheric deposition sampler intercomp
✍ Richard C. Graham; John K. Robertson; Leroy Schroder πŸ“‚ Article πŸ“… 1988 πŸ› Springer Netherlands 🌐 English βš– 505 KB