A novel transverse gradient coil design for high-resolution mr imaging
โ Scribed by Cynthia F. Maier; Kenneth C. Chu; Blaine A. Chronik; Brian K. Rutt
- Publisher
- John Wiley and Sons
- Year
- 1995
- Tongue
- English
- Weight
- 742 KB
- Volume
- 34
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
โฆ Synopsis
Abstract
The authors describe a new gradient coil design for high resolution human, animal, specimen, or phantom imaging with high gradient efficiency and a large region of excellent gradient uniformity. Important features of our new design are the simple analytical description of the wire patterns that comprise the design, and ease of construction. Wires are spaced in a sinusoidal distribution around the circumference of the cylinder, and curved in an arcsin shape along the length of the cylinder. This coil produces a magnetic field pointing in a direction transverse to the axis of the coil with a gradient in the direction parallel to the axis of the coil. The same arcsin coil can be used to create a magnetic field pointing in a direction parallel to its axis with a gradient in a direction perpendicular to the coil axis. A prototype coil was constructed; field and inductance calculations were verified. Geometric variations on this coil design were modeled and their performance characteristics compared. This coil design is ideal for rapid implementation of a transverse gradient coil, since no specialized design software is required.
๐ SIMILAR VOLUMES
A solenoidal RF coil is presented that generates an RF field only perpendicular to the long axis, so that it can be used longitudinally in the usual superconducting solenoid magnet for NMR. This new design is superior to the traditional saddle coil or Helmholtz pair. Applications for the coil will i
## Abstract A shielded gradient system and radio frequency probes for a 4.7โT/30โcm horizontal bore magnet are described. The systems were designed principally to obtain images and localized spectra from rat brains. The gradients can operate in either a shielded or non shielded mode. The rf probe,
## Abstract The geometry of an RF phasedโarray receiving coil for highโresolution MRI of the carotid artery, particularly the bifurcation, was optimized with respect to signalโtoโnoise ratio (SNR). A simulation tool was developed to determine homogeneity, sensitivity, and SNR for a given imaging si
## Abstract ## Purpose To evaluate the ability of a customโbuilt coil design to provide improved signalโtoโnoise ratio (SNR) and less signal drop with increasing depth at the carotid artery. ## Materials and Methods Phasedโarray surface coils can provide a high SNR to image the carotid vessel wa