Abstract
Infection of biomaterial implants is an expensive and devastating complication of orthopaedic surgery historically ranging from less than 1% in primary total knee arthroplasty (TKA) to 10% in revision TKA. An in vivo animal model was developed to test the efficacy of innovative therapies for the prevention of biomaterial centered infections caused by methicillinβresistant Staphylococcus aureus bacteria (MRSA). Twentyβtwo New Zealand White rabbits were used in this study. After proper anesthesia, a stainlessβsteel screw with a high molecular weight polyethylene (UHMWPE) washer was cemented in a defect created in the intraβarticular, nonarticulating portion of the lateral femoral condyle of each knee. After closure of the joint capsule, each knee was inoculated with 0, 10^2^, 10^3^, or 10^4^ colony forming units (CFU) of MRSA. Animals were sacrificed after 7 days at which time joint aspirate, tissues and biomaterial samples were examined for evidence of infection.
A total of 42 knees were used for analysis. When saline was injected into the knee, 0/10 of the knees demonstrated evidence of biomaterial centered infection (with the contralateral knee receiving 10^4^ CFU MRSA). Four of 10 knees developed a biomaterial centered infection when 10^2^ CFU MRSA was introduced. Seven out of 10 knees developed a biomaterial centered infection when either 10^3^ or 10^4^ CFU MRSA was injected. No evidence of septicemia (positive blood cultures) was found in any animal. This rabbit knee model utilizes commonly employed inexpensive orthopaedic implant materials in an in vivo milieu and provides an effective method for the evaluation of treatments for biomaterial centered infections. Β© 2005 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.
π SIMILAR VOLUMES
## Abstract A novel intramedullary plug with sliding mechanism has been developed and evaluated clinically in the settings of revision total knee arthroplasty (TKA). The new plug consists of a pair of specially designed components. Each component is shaped like an obliquely cut cylinder. Postoperat
Despite the numerous long-term success reports of posterior stabilized (PS) total knee arthroplasty (TKA), recent retrieval studies of various PS TKA designs revealed wear and deformation on the anterior side of the tibial post. This study investigated the mechanisms of anterior impingement of the p
## Abstract ## Background One of the goals of total knee arthroplasty (TKA) is to balance the loads between the compartments of the knee. An instrumented load cell that measures compartment loads in real time is utilized to evaluate conventional, qualitative methods of achieving this balance. ##
An understanding of the absorption of antibiotics from joints was investigated comparing intraarticular (La.) absorption with intramuscular (im.) absorption in a rabbit knee model. The antibiotics investigated were methicillin, cephalothin, cefazolin, cefoxitin, amikacin, neomycin, kanamycin, and ge