A new scanning technique for reducing artifacts due to the partial volume effect is presented which maintains the spatial resolution of the conventional method. These artifacts are stripes and they have a ring shape between the source and the rotation center. Experimental and simulation results are
✦ LIBER ✦
A new method of performance verification for x-ray computed tomography measurements
✍ Scribed by Léonard, F; Brown, S B; Withers, P J; Mummery, P M; McCarthy, M B
- Book ID
- 127106139
- Publisher
- Institute of Physics
- Year
- 2014
- Tongue
- English
- Weight
- 784 KB
- Volume
- 25
- Category
- Article
- ISSN
- 0957-0233
No coin nor oath required. For personal study only.
📜 SIMILAR VOLUMES
A new scanning technique for X-ray compu
✍
Jun Nukaga; So Kitazawa; Hiroshi Kamimura
📂
Article
📅
2008
🏛
Elsevier Science
🌐
English
⚖ 920 KB
A new preparation method to study fresh
✍
O. LEROUX; F. LEROUX; E. BELLEFROID; M. CLAEYS; M. COUVREUR; G. BORGONIE; L. VAN
📂
Article
📅
2009
🏛
John Wiley and Sons
🌐
English
⚖ 136 KB
Advances in X-ray Tomography for Geomate
✍
Desrues, Jacques; Viggiani, Gioacchino; Bsuelle, Pierre
📂
Article
📅
2006
🏛
ISTE
⚖ 608 KB
A wall-thickness-based method of adaptiv
✍
J. Hofmann; A. Flisch
📂
Article
📅
2006
🏛
Elsevier Science
🌐
English
⚖ 624 KB
This paper introduces a method to reduce the acquisition time of X-ray computed tomography (XCT) scanners with line detectors. For every slice (cross-sectional image), the maximum wall thickness (WT) of an object is calculated. WT and signal-to-noise ratio (SNR) of the XCT detector signal correlate
Characteristics of a silicon detector fo
✍
H. Miyai; H. Kitaguchi; S. Kawasaki; S. Izumi
📂
Article
📅
1994
🏛
Elsevier Science
🌐
English
⚖ 286 KB
A new approach to synchrotron energy-dis
✍
Lazzari, Olivier ;Egan, Christopher K. ;Jacques, Simon D. M. ;Sochi, Taha ;Di Mi
📂
Article
📅
2012
🏛
International Union of Crystallography
🌐
English