A model-based block-triangular preconditioner for the Bidomain system in electrocardiology
β Scribed by L. Gerardo-Giorda; L. Mirabella; F. Nobile; M. Perego; A. Veneziani
- Publisher
- Elsevier Science
- Year
- 2009
- Tongue
- English
- Weight
- 582 KB
- Volume
- 228
- Category
- Article
- ISSN
- 0021-9991
No coin nor oath required. For personal study only.
β¦ Synopsis
We introduce a preconditioner for the solution of the Bidomain system governing the propagation of action potentials in the myocardial tissue. The Bidomain model is a degenerate parabolic set of nonlinear reaction-diffusion equations. The nonlinear term describes the ion flux at the cellular level. The degenerate nature of the problem results in a severe ill conditioning of its discretization. Our preconditioning strategy is based on a suitable adaptation of the Monodomain model, a simplified version of the Bidomain one, which is by far simpler to solve, nevertheless is unable to capture significant features of the action potential propagation. The Monodomain preconditioner application to a non-symmetric formulation of the Bidomain system results at the algebraic level in a lower block-triangular preconditioner. We prove optimality of the preconditioner with respect to the mesh size, and corroborate our theoretical results with 3D numerical simulations both on idealized and real ventricle geometries.
π SIMILAR VOLUMES