𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A method for the determination of low-level organic-bound tritium activities in environmental samples

✍ Scribed by F Pointurier; N Baglan; G Alanic


Publisher
Elsevier Science
Year
2004
Tongue
English
Weight
210 KB
Volume
61
Category
Article
ISSN
0969-8043

No coin nor oath required. For personal study only.


πŸ“œ SIMILAR VOLUMES


A rapid method for the determination of
✍ Chuarn-Yuh Huang; Jun-Der Lee; Chia-Lian Tseng; Jem-Mau Lo πŸ“‚ Article πŸ“… 1994 πŸ› Elsevier Science 🌐 English βš– 473 KB

This work deals with a simple, rapid, and efficacious design for the measurement of 137Cs in seawater . An adsorption filter is fabricated by coating copper(II) hexacyanoferrate(II) (CuCF) onto a densely twilled nylon cloth . The CuCF-nylon cloth filter is cut into round pieces and screwed into a po

A novel inhibitory kinetic fluorimetric
✍ Jing Fan; Xiaojing Shao; Haizhu Xu; Suling Feng πŸ“‚ Article πŸ“… 2009 πŸ› John Wiley and Sons 🌐 English βš– 162 KB πŸ‘ 2 views

## Abstract A novel inhibitory kinetic fluorimetric method for the determination of trace methomyl was proposed. It was shown that the Fenton reagent oxidized rhodamine B in acid medium which enabled the fluorescence quenching of the latter. The presence of trace methomyl clearly inhibited the reac

A Simplified Analytical Procedure for th
✍ Borsdorf, Helko ;Fiedler, Petra ;Wilke, Dorit ;Weiß, Holger πŸ“‚ Article πŸ“… 2003 πŸ› John Wiley and Sons 🌐 English βš– 80 KB πŸ‘ 2 views

## Abstract A method was developed for the determination of organic halogens in water samples with the aim of minimizing matrix effects and simplifying the sample preparation technique commonly used. The method is based on the adsorption of organic halogens in modified hydrophilic divinylbenzene po

Development of a screening method for th
✍ Lothar Dunemann; Hossein Hajimiragha πŸ“‚ Article πŸ“… 1993 πŸ› Elsevier Science 🌐 English βš– 648 KB

A sensitive screening method with low sample consumption is presented for the simultaneous determination of 48 volatile organic compounds (VOCs) by capillary gas chromatography with flame ionization detection (FID) or mass spectrometric ion trap detection (ITD). The method is applicable to body flui

A simple and rapid hydride generationβ€”at
✍ R.G. Smith; J.C. Van Loon; J.R. Knechtel; J.L. Fraser; A.E. Pitts; A.E. Hodges πŸ“‚ Article πŸ“… 1977 πŸ› Elsevier Science 🌐 English βš– 581 KB

An inexpensive 50-ml disposable (hypodermic) syringe is used as the arsine generation vessel. The arsine is passed into a lo-cm long. lo-mm i.d. electrically heated silica tube atomizer with nitrogen carrier gas. Jkcess of hydrogen is burned off in a hydrogen diffusion flame at the ends of the tube.