𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A method for production and characterization of metal prosthesis wear particles

✍ Scribed by Susan D. Rogers; Dr. Mark J. Pearcy; Shelley J. Hay; David R. Haynes; Allan Bramley; Donald W. Howie


Publisher
Elsevier Science
Year
1993
Tongue
English
Weight
852 KB
Volume
11
Category
Article
ISSN
0736-0266

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The wear of joint prostheses generates wear particles that produce an inflammatory response in the surrounding tissues and may contribute to bone resorption resulting in prosthetic loosening. Although the effects of particles produced from prosthetic materials have been studied extensively in vitro and in vivo, little attention has been paid to the standardisation of methods for the generation and characterization of these particles. This paper describes a reproducible method for generation of metal particles by the abrasive shaking of joint replacement components. Particular attention was given to the production of metal particles that closely resembled particles found around solid and loose human prostheses. To achieve this, particle size, size distribution, chemical composition, and shape were characterized. Particles that were 0.5–3.0 ΞΌm in diameter were isolated by differential sedimentation, and the distribution of particle sizes was determined with use of a Coulter Multisizer. Chemical composition was measured by atomic absorption spectrophotometry, and transmission electron microscopy was used to characterize particle shape. The techniques were shown to be reproducible, since there was little variation between batches over a lengthy time period. These or similar methods of particle production and characterization should be an essential part of future in vitro and in vivo studies of wear particles.


πŸ“œ SIMILAR VOLUMES


Wear evaluation of cobalt-chromium alloy
✍ St. John, Kenneth R. ;Zardiackas, Lyle D. ;Poggie, Robert A. πŸ“‚ Article πŸ“… 2003 πŸ› John Wiley and Sons 🌐 English βš– 270 KB

## Abstract Wear of the polyethylene in total joint prostheses has been a source of morbidity and early device failure, which has been extensively reported in the last 20 years. Although research continues to attempt to reduce the wear of polyethylene joint‐bearing surfaces by modifications in poly

Metal wear particle characterization fro
✍ Doorn, Peter F. ;Campbell, Patricia A. ;Worrall, Jack ;Benya, Paul D. ;McKellop, πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 512 KB

The less intense tissue reaction around metal on metal total hip replacements (THRs) compared to metal on polyethylene (PE) THRs may be explained by the differences in the characteristics of metal wear particles. In this study, transmission electron microscopy was used to study metal wear particles

Effects of digestion protocols on the is
✍ Catelas, Isabelle ;Bobyn, J. Dennis ;Medley, John J. ;Zukor, David J. ;Petit, Al πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 238 KB πŸ‘ 1 views

The isolation of metal wear particles from hip simulator lubricants is important for understanding wear mechanisms and the tissue response to particulate material. Part I of this study demonstrated that isolation protocols involving digestion reagents can chemically attack metal-metal wear particles

Production of refractory-metal ultrafine
✍ Yuki Kimura; Chihiro Kaito πŸ“‚ Article πŸ“… 2008 πŸ› Elsevier Science 🌐 English βš– 540 KB

Generally, molybdenum, tungsten or tantalum is used as the evaporation source of many kinds of materials because of their high melting points and reasonably low vapor pressures. Therefore, the production of ultrafine particles of molybdenum, tungsten and tantalum has not been achieved by gas evapora