## Abstract __In vivo__ ^23^Na magnetic resonance images of guinea pig kidney were obtained at 2.1 T using a spin‐echo sequence with an echo time of 19 ms. The intact kidney showed a very strong signal intensity in the sodium image. The signal intensity of the kidney decreased to 55% after ligation
A method for in vivo MR imaging of the short T2 component of sodium-23
✍ Scribed by J. B. Ra; S. K. Hilal; Z. H. Cho
- Publisher
- John Wiley and Sons
- Year
- 1986
- Tongue
- English
- Weight
- 392 KB
- Volume
- 3
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
A magnetic resonance imaging pulse sequence featuring a short echo time of 3.6 ms is described and used clinically for in vivo imaging of sodium-23 in the human head. In living tissues, sodium exhibits at least two transverse relaxation constants, namely, (a) a short component T2s = 0.7-3.0 ms and (b) a long component TzP = 16-30 ms. Since our first in vivo imaging of sodium, an echo time of 10-15 ms has been used by us and by other investigators. This echo time is adequate for the observation of the long T2 component of sodium. However, a substantial fraction of the sodium, namely, the short T2 component, representing about 4070, has remained undetected by the imaging method with this echo time and is now observable by the new pulse sequence. The proposed method is a hybrid technique combining both projection reconstruction and Fourier encoding schemes. The projection reconstruction is used for the xy plane imaging while the Fourier encoding is used for slice separation. Sodium MR images of the human head produced with a short and a long T, are presented and analyzed. There is an increase in the MR signal and improved visibility of intraparenchymal sodium with the new scheme of short TE. o 1986 Academic Press. Inc.
📜 SIMILAR VOLUMES
## Abstract In vivo proton MR spectroscopic imaging (MRSI) of human brain is complicated by the presence of a strong signal from subcutaneous lipids, which may result in signal contamination in metabolite images obtained following Fourier‐transform reconstruction. In this study, two approaches for
## Abstract ACUT~2~E TSE‐SSFP is a hybrid between steady state free precession (SSFP) and turbo spin echo (TSE) for bright‐blood T2‐weighted imaging with signal‐to‐noise ratio (SNR) and contrast‐to‐noise ratio (CNR) similar to dark‐blood TSE. TSE‐SSFP uses a segmented SSFP readout during diastole w
## Abstract The rotating frame method of localized spectroscopy can be augmented by the inclusion of a refocusing pulse to enable the measurement of T~2~ relaxation times. This technique is particularly appropriate for determining short relaxation parameters due to the absence of time consuming swi
## Abstract ## Purpose To investigate the feasibility of obtaining high‐resolution MR images for the detection of pathological changes occurring in the injured rat spinal cord with a routine clinical 3.0T imaging system. ## Materials and Methods Adult female Fischer 344 rats received thoracic sp
The purpose of this study was to correlate the abnormal signal area on various magnetic resonance (MR) images to the infarct area on pathologic examination and to assess the myocardial viability on the basis of MR images. T2weighted, first-pass perfusion, and delayed gadolinium-enhanced T1-weighted