A method for improving the performance of gradient systems for diffusion-weighted MRI
✍ Scribed by Zoltan Nagy; Nikolaus Weiskopf; Daniel C. Alexander; Ralf Deichmann
- Publisher
- John Wiley and Sons
- Year
- 2007
- Tongue
- English
- Weight
- 335 KB
- Volume
- 58
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The MR signal is sensitive to diffusion. This effect can be increased by the use of large, balanced bipolar gradients. The gradient systems of MR scanners are calibrated at installation and during regular servicing visits. Because the measured apparent diffusion constant (ADC) depends on the square of the amplitude of the diffusion sensitizing gradients, errors in the gradient calibration are exaggerated. If the error is varying among the different gradient axes, it will affect the estimated degree of anisotropy. To assess the gradient calibration accuracy in a whole‐body MRI scanner, ADC values were calculated for a uniform water phantom along each gradient direction while monitoring the temperature. Knowledge of the temperature allows the expected diffusion constant of water to be calculated independent of the MRI measurement. It was found that the gradient axes (±x, ±y, ±z) were calibrated differently, resulting in offset ADC values. A method is presented to rescale the amplitude of each of the six principal gradient axes within the MR pulse sequence. The scaling factor is the square root of the ratio of the expected and observed diffusion constants. In addition, fiber tracking results in the human brain were noticeably affected by improving the gradient system calibration. Magn Reson Med 58:763–768, 2007. © 2007 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract ## Purpose: To retrospectively determine the additional value of diffusion‐weighted magnetic resonance imaging (MRI) to T2‐weighted imaging in the evaluation of anal fistulae in comparison with gadolinium (Gd)‐enhanced imaging. ## Materials and Methods: Thirteen patients (mean age, 3
Over the past decade several pulsed field gradient stimulated-echo methods have been presented for diffusion measurements in heterogeneous media. These methods have reduced or eliminated the coupling between the applied magnetic field gradient and a constant internal magnetic field gradient caused b
The network approach is a method whereby physicochemical systems are replaced by electrical networks, which are simulated by using a digital computer program such as PSPICE. The network method solves problems of great mathematical complexity in a versatile and efficient way. This method has been app
## Abstract A method for improving broadband phase performance of common‐source/common‐gate (CS/CG) active balun is presented. By setting different terminal impedances and DC bias, the phase error of the balun can be controlled within 7° from 1 to 20 GHz in simulation. A fabricated 2–40 GHz balance