𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A magnetic field controlled negative-index microwave lens

✍ Scribed by R. V. Petrov; R. Pandey; G. Srinivasan; M. I. Bichurin


Book ID
102518922
Publisher
John Wiley and Sons
Year
2008
Tongue
English
Weight
391 KB
Volume
50
Category
Article
ISSN
0895-2477

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A three‐dimensional lens with magnetic field control of the index of refraction and focal length has been designed and characterized over 2‐18 GHz. The lens is made of a lattice of cross‐wire resonators and ferrite cubes. For the lattice without the ferrite cubes, a refractive index n β‰ˆ βˆ’1 is measured at 11.25 GHz. With the introduction of ferrite cubes in the lattice, n could be tuned over the range βˆ’1.2 to +1.8 for nominal bias magnetic fields H. The focal point for the lens with n β‰ˆ βˆ’1, for example, could be displaced by 2 cm by tuning H from 4100 to 4125 Oe. Theoretical estimates of the lens characteristics are in agreement with the data. Β© 2008 Wiley Periodicals, Inc. Microwave Opt Technol Lett 50: 2804–2807, 2008; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.23847