✦ Synopsis


An efficient ion transport system that interfaces external ion sources with a commercial dual-cell Fourier transform mass spectrometry (FTMS) system so as to retain maximum experimental flexibility has been constructed. Electrostatic lenses were used for ion transfer with potentials less than 200 V to preclude discharges. Spectra were recorded by thermal ionization and by electrospray ionization. Other high pressure ionization methods can be easily added to the external ion source chamber, making this a general solution for ion transport into an FTMS system. The efficiency of ion transfer was measured to be approximately 30%. A pressure ratio of 10(5) between the external ion source chamber and the second cell has been demonstrated. The system incorporates a computer-controlled gate valve to isolate the cell regions from the external ion source chamber, permitting optimal conditions for ion injection and accumulation, and then after closing the valve, recording spectra at low pressure with high resolution. Spectra of Gramicidin S (resolution 90,000 at m/z 1164), aprotinin (resolution 410,000 at m/z 1304), and horse heart cytochrome c (resolution 50,000 at m/z 1546) are shown.


πŸ“œ SIMILAR VOLUMES


Desorption/Ionization of Inorganic Compo
✍ Herbert Struyf; Luc Van Vaeck; RenΓ© Van Grieken πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 896 KB

Application of FT LMMS to inorganic compounds offers the advantage of direct speciation. This means that signals which refer to intact analyte molecules are detected. Cumnt concepts of desorption and ionization in LMMS are mainly based on time-of-llight data and hence on ions formed during the laser

Pulsed-valve chemical ionization for gas
✍ David A. Laude Jr.; Carolyn L. Johlman; Robert S. Brown; Carl F. Ijames; Charles πŸ“‚ Article πŸ“… 1985 πŸ› Elsevier Science 🌐 English βš– 665 KB

The pressure requirements for chemical ionization g.c./F.t.m.s. which restrict mass resolution and accuracy are overcome through use of a pulsed valve that provides momentary reagent gas pressures. For alternate electron impact (EI)/chemical ionization (c.i.) g.c./F.t.m.s., similar resolution for bo

Ion kinetic energy modulation for improv
✍ C.L. Hendrickson; J.J. Drader; D.A. Laude Jr. πŸ“‚ Article πŸ“… 1995 πŸ› Elsevier Science 🌐 English βš– 260 KB

A new technique for manipulating the kinetic energy distribution of electrospray ions that arrive at a Fourier transform ion cyclotron resonance trapped-ion cell is presented. Narrow kinetic energy distributions can complicate the selection of appropriate trapping conditions for electrospray ions an

An improved ion guide for external ion i
✍ Christopher M. Barshick; John R. Eyler πŸ“‚ Article πŸ“… 1993 πŸ› Elsevier Science 🌐 English βš– 646 KB

To improve the existing ion transport optics of our glow discharge (GD)-Fourier transformion cyclotron resonance (FT-ICR) mass spectrometer, we simulated several ion trajectories between the GD source region and the ICR analyzer cell. These calculations suggested that a number of simple improvements