Application of FT LMMS to inorganic compounds offers the advantage of direct speciation. This means that signals which refer to intact analyte molecules are detected. Cumnt concepts of desorption and ionization in LMMS are mainly based on time-of-llight data and hence on ions formed during the laser
A low voltage ion transport system for external ionization fourier transform mass spectrometry
β Scribed by Carl F. Ijames; Sanford P. Markey
- Publisher
- Elsevier Science
- Year
- 1994
- Tongue
- English
- Weight
- 970 KB
- Volume
- 5
- Category
- Article
- ISSN
- 1044-0305
No coin nor oath required. For personal study only.
β¦ Synopsis
An efficient ion transport system that interfaces external ion sources with a commercial dual-cell Fourier transform mass spectrometry (FTMS) system so as to retain maximum experimental flexibility has been constructed. Electrostatic lenses were used for ion transfer with potentials less than 200 V to preclude discharges. Spectra were recorded by thermal ionization and by electrospray ionization. Other high pressure ionization methods can be easily added to the external ion source chamber, making this a general solution for ion transport into an FTMS system. The efficiency of ion transfer was measured to be approximately 30%. A pressure ratio of 10(5) between the external ion source chamber and the second cell has been demonstrated. The system incorporates a computer-controlled gate valve to isolate the cell regions from the external ion source chamber, permitting optimal conditions for ion injection and accumulation, and then after closing the valve, recording spectra at low pressure with high resolution. Spectra of Gramicidin S (resolution 90,000 at m/z 1164), aprotinin (resolution 410,000 at m/z 1304), and horse heart cytochrome c (resolution 50,000 at m/z 1546) are shown.
π SIMILAR VOLUMES
The pressure requirements for chemical ionization g.c./F.t.m.s. which restrict mass resolution and accuracy are overcome through use of a pulsed valve that provides momentary reagent gas pressures. For alternate electron impact (EI)/chemical ionization (c.i.) g.c./F.t.m.s., similar resolution for bo
A new technique for manipulating the kinetic energy distribution of electrospray ions that arrive at a Fourier transform ion cyclotron resonance trapped-ion cell is presented. Narrow kinetic energy distributions can complicate the selection of appropriate trapping conditions for electrospray ions an
To improve the existing ion transport optics of our glow discharge (GD)-Fourier transformion cyclotron resonance (FT-ICR) mass spectrometer, we simulated several ion trajectories between the GD source region and the ICR analyzer cell. These calculations suggested that a number of simple improvements