A predictive approach using fractal analysis is presented for analyte-receptor binding and dissociation kinetics for biosensor applications. Data taken from the literature may be modeled, in the case of binding using a single-fractal analysis or a dual-fractal analysis. The dual-fractal analysis rep
A Kinetic Study of Analyte–Receptor Binding and Dissociation, and Dissociation Alone, for Biosensor Applications: A Fractal Analysis
✍ Scribed by Ajit Sadana
- Publisher
- Elsevier Science
- Year
- 2001
- Tongue
- English
- Weight
- 152 KB
- Volume
- 291
- Category
- Article
- ISSN
- 0003-2697
No coin nor oath required. For personal study only.
✦ Synopsis
A fractal analysis is presented for (a) analyte-receptor binding and dissociation kinetics and (b) dissociation kinetics alone for biosensor applications. Emphasis is placed on dissociation kinetics. Data taken from the literature may be modeled, in the case of binding, using a single-fractal analysis or a dual-fractal analysis. The dual-fractal analysis represents a change in the binding mechanism as the reaction progresses on the surface. A single-fractal analysis is adequate to model the dissociation kinetics in the examples presented. Predictive relationships developed for the dissociation rate coefficient(s) as a function of the analyte concentration are of particular value since they provide a means by which the dissociation rate coefficients may be manipulated. Relationships are also presented for the binding and dissociation rate coefficients as a function of their corresponding fractal dimension, D(f), or the degree of heterogeneity that exists on the surface. When analyte-receptor binding or dissociation is involved, an increase in the heterogeneity on the surface (increase in D(f)) leads to an increase in the binding and in the dissociation rate coefficient.
📜 SIMILAR VOLUMES
The diffusion-limited binding kinetics of analyte in solution to either a receptor immobilized on a surface or to a receptorless surface is analyzed within a fractal framework for a surface plasmon resonance biosensor. The data is adequately described by a single-or a dual-fractal analysis. Initiall
A fractal analysis is presented for cellular analyte-receptor binding kinetics utilizing biosensors. Data taken from the literature can be modeled by using (a) a single-fractal analysis and (b) a single- and a dual-fractal analysis. Case (b) represents a change in the binding mechanism as the reacti
The diffusion-limited binding kinetics of antigen (analyte) in solution to antibody (receptor) immobilized on a biosensor surface is analyzed within a fractal framework. Most of the data presented are adequately described by a single-fractal analysis. This was indicated by the regression analysis pr
antigens) in a solution. The binding of an antigen to an The diffusion-limited kinetics of binding of an analyte in soluantibody-coated surface (or vice versa) is sensed directly tion to a receptor immobilized on a biosensor surface is analyzed and rapidly. There is a need to characterize the reacti
The diffusion-limited binding kinetics of antigen (or antibody) in solution to antibody (or antigen) immobilized on a biosensor surface is analyzed within a fractal framework. The fit obtained by a dual-fractal analysis is compared with that obtained from a single-fractal analysis. In some cases, th