𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A fully validated method for the determination of vardenafil in blood using gas chromatography/mass spectrometry

✍ Scribed by Ioannis Papoutsis; Panagiota Nikolaou; Sotirios Athanaselis; Constantinos Pistos; Constantinos Maravelias; Chara Spiliopoulou


Publisher
John Wiley and Sons
Year
2010
Tongue
English
Weight
184 KB
Volume
46
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Vardenafil (VDN) is one of the three commercially available phosphodiesterase type 5 inhibitors and it is mainly used in the treatment of erectile dysfunction. A sensitive and specific gas chromatography/mass spectrometry (GC/MS) method for the determination of VDN in blood has been developed and validated. Sample preparation included solid‐phase extraction and derivatization with N‐methyl‐Ntert‐butyldimethylsilyl‐trifluoroacetamide (MTBSTFA) and 1% tert‐butyldimethylsilylchloride (TBDMSCl). Protriptyline was used as the internal standard for this assay. Limits of detection and quantification for VDN were 0.70 and 2.00 µg/l, respectively. The calibration curves were linear within the dynamic range 2.00–200.0 µg/l with a correlation coefficient higher than 0.991. Absolute recovery ranged from 88.6% to 95.7% for the analyte of interest at three quality control levels. Intra‐ and inter‐day accuracy was found to be between − 6.1% to 10.8% and − 9.3% to 11.6%, respectively, whereas intra‐ and inter‐day precision was < 7.8% and 9.7%, correspondingly. The proposed method is the first fully validated GC/MS method for the determination of VDN in blood samples and it can be used in routine every day analysis by clinical and forensic laboratories for pharmacokinetic studies, for therapeutic drug level monitoring or for the investigation of related forensic cases. A few blood samples analyzed using the developed method is reported herein to demonstrate the suitability of the method. Copyright © 2010 John Wiley & Sons, Ltd.


📜 SIMILAR VOLUMES


Method validation for the determination
✍ Ondřej Fryš; Petra Bajerová; Aleš Eisner; Martina Mudruňková; Karel Ventura 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 147 KB 👁 1 views

## Abstract A fast, sensitive, and accurate GC/MS method for the quantification of aliphatic nitroesters (ethylene glycol dinitrate, nitroglycerin, and triethylene glycol dinitrate) and aromatic amines (diphenylamine, 2‐nitrodiphenylamine, and triphenylamine) in propellants was developed and valida

Development and validation of a gas chro
✍ Ioannis Papoutsis; Panagiota Nikolaou; Sotirios Athanaselis; Giorgos Alevizopoul 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 111 KB 👁 1 views

## Abstract Sildenafil (SDL) is a phosphodiesterase type 5 inhibitor and it is approved for the treatment of erectile dysfunction and pulmonary hypertension. SDL is extensively metabolized to its pharmacologically active metabolite, desmethyl‐sildenafil (DSDL). A sensitive and specific GC/MS method

Development and validation of a gas chro
✍ Qinhua Chen; Kaijun Li; Zhuo Zhang; Peng Li; Jia Liu; Qiang Li 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 123 KB 👁 2 views

## Abstract Phenazopyridine hydrochloride is a strong analgesic used in the treatment of urinary tract infections. The aim of the present study was to develop a procedure based on gas chromatography‐mass spectrometry (GC‐MS) for the analysis of phenazopyridine in rat plasma. The method was set up a

Determination of Kinetic Isotope Effects
✍ Paul C. Kline; Mansoureh Rezaee; Terrence A. Lee 📂 Article 📅 1999 🏛 Elsevier Science 🌐 English ⚖ 69 KB

Kinetic isotope effects are widely used to determine the transition state of chemical and enzymatic reactions. Radioactive isotopes are used most often to determine these kinetic isotope effects. However, stable isotopes offer a number of advantages over the use of radioactive isotopes. These advant

Comparison of different extraction metho
✍ Soon-Kil Cho; A. M. Abd El-Aty; Hyang-Rang Jeon; Jeong-Heui Choi; Ho-Chul Shin; 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 141 KB 👁 2 views

## Abstract The methods of simultaneous extraction of iprodione, chlorpyrifos‐methyl, EPN and endosulfan (with its metabolites) from kiwi fruit using accelerated solvent extraction (ASE), supercritical fluid extraction (SFE), and liquid–liquid extraction (LLE) were tested and compared in terms of t