## Abstract A fast, sensitive, and accurate GC/MS method for the quantification of aliphatic nitroesters (ethylene glycol dinitrate, nitroglycerin, and triethylene glycol dinitrate) and aromatic amines (diphenylamine, 2‐nitrodiphenylamine, and triphenylamine) in propellants was developed and valida
A fully validated method for the determination of vardenafil in blood using gas chromatography/mass spectrometry
✍ Scribed by Ioannis Papoutsis; Panagiota Nikolaou; Sotirios Athanaselis; Constantinos Pistos; Constantinos Maravelias; Chara Spiliopoulou
- Publisher
- John Wiley and Sons
- Year
- 2010
- Tongue
- English
- Weight
- 184 KB
- Volume
- 46
- Category
- Article
- ISSN
- 1076-5174
- DOI
- 10.1002/jms.1868
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Vardenafil (VDN) is one of the three commercially available phosphodiesterase type 5 inhibitors and it is mainly used in the treatment of erectile dysfunction. A sensitive and specific gas chromatography/mass spectrometry (GC/MS) method for the determination of VDN in blood has been developed and validated. Sample preparation included solid‐phase extraction and derivatization with N‐methyl‐N‐tert‐butyldimethylsilyl‐trifluoroacetamide (MTBSTFA) and 1% tert‐butyldimethylsilylchloride (TBDMSCl). Protriptyline was used as the internal standard for this assay. Limits of detection and quantification for VDN were 0.70 and 2.00 µg/l, respectively. The calibration curves were linear within the dynamic range 2.00–200.0 µg/l with a correlation coefficient higher than 0.991. Absolute recovery ranged from 88.6% to 95.7% for the analyte of interest at three quality control levels. Intra‐ and inter‐day accuracy was found to be between − 6.1% to 10.8% and − 9.3% to 11.6%, respectively, whereas intra‐ and inter‐day precision was < 7.8% and 9.7%, correspondingly. The proposed method is the first fully validated GC/MS method for the determination of VDN in blood samples and it can be used in routine every day analysis by clinical and forensic laboratories for pharmacokinetic studies, for therapeutic drug level monitoring or for the investigation of related forensic cases. A few blood samples analyzed using the developed method is reported herein to demonstrate the suitability of the method. Copyright © 2010 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
## Abstract Sildenafil (SDL) is a phosphodiesterase type 5 inhibitor and it is approved for the treatment of erectile dysfunction and pulmonary hypertension. SDL is extensively metabolized to its pharmacologically active metabolite, desmethyl‐sildenafil (DSDL). A sensitive and specific GC/MS method
## Abstract Phenazopyridine hydrochloride is a strong analgesic used in the treatment of urinary tract infections. The aim of the present study was to develop a procedure based on gas chromatography‐mass spectrometry (GC‐MS) for the analysis of phenazopyridine in rat plasma. The method was set up a
Kinetic isotope effects are widely used to determine the transition state of chemical and enzymatic reactions. Radioactive isotopes are used most often to determine these kinetic isotope effects. However, stable isotopes offer a number of advantages over the use of radioactive isotopes. These advant
## Abstract The methods of simultaneous extraction of iprodione, chlorpyrifos‐methyl, EPN and endosulfan (with its metabolites) from kiwi fruit using accelerated solvent extraction (ASE), supercritical fluid extraction (SFE), and liquid–liquid extraction (LLE) were tested and compared in terms of t