A fretting wear study of a nitrogen implanted titanium alloy
β Scribed by N. C. Horswill; K. Sridharan; J. R. Conrad
- Publisher
- Springer
- Year
- 1995
- Tongue
- English
- Weight
- 1000 KB
- Volume
- 14
- Category
- Article
- ISSN
- 0261-8028
No coin nor oath required. For personal study only.
π SIMILAR VOLUMES
Rolling element bearings experience fretting wear type of failures due to small relative oscillatory motion existing between races and rolling elements of the bearing. Small oscillatory motion between contacting surfaces that occur due to overall machine or system vibration and unexpected loads in s
## Abstract Samples of two titanium alloys, Tiβ6Alβ4V and Tiβ15Vβ3Crβ3Snβ3Al, were ion implanted with a combination of nitrogen (N^+^) and oxygen (O^+^). For each alloy, implantation parameters were chosen to give implanted nitrogen concentrations of βΌ10 or 50 at.%, from a depth of 100 nm to a dept