β¦ Synopsis
This paper deals with the simulation of thermal energy storage (TES) system for HVAC applications. TES is considered to be one of the most preferred demand side management technologies for shifting cooling electrical demand from peak daytime hours to off peak night hours. TES is incorporated into the conventional HVAC system to store cooling capacity by chilling ethylene glycol, which is used as a storage medium. The thermodynamic performance is assessed using exergy and energy analyses. The effects of various parameters such as ambient temperature, cooling load, and mass of storage are studied on the performance of the TES. A full storage cycle, with charging, storing and discharging stages, is considered. In addition, energy and exergy analysis of the TES is carried out for system design and optimization. The temperature in the storage is found to be as low as 6.48C after 1 day of charging without load for a mass of 250 000 kg. It is found that COP of the HVAC system increases with the decrease of storage temperature. Energy efficiency of the TES is found to be 80% for all the mass flow rate of the discharging fluid, whereas exergy efficiency varies from 14 to 0.5%. This is in fact due to the irreversibilities in a TES process destroy a significant amount of the input exergy, and the TES exergy efficiencies therefore become always lower than the corresponding energy efficiencies.
π SIMILAR VOLUMES
In this paper, a solid desiccant cooling system with a backup vapour compression system is simulated using TRNSYS and the performance of the system is evaluated in four cities in the United States with different climates. Economic analysis is performed in order to assess the feasibility of these sys
A desiccant dehumidifier in conjunction with evaporative coolers can reduce air conditioning operating costs significantly since the energy required to power a desiccant cooling system is small and the source of this required energy (solar, waste heat, natural gas) can be diverse. Such a solid desic
## Abstract An energy storage system that stores energy in the form of liquid air was studied. In this system, the cool storage unit was the most important unit. From the viewpoint of safety and economy, it was most promising to store the cold energy as the sensitive heat of a solid such as pebbles
## Abstract Field investigations were carried out for 3 years with the aim of studying the feasibility of using microsprinkler and drip irrigation systems for vegetable production in a canal command area. These systems were compared with the existing flood irrigation method for onion production wit