𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A fast simple hot-wire method of determining the mean velocity vector of complex three-dimensional flows

✍ Scribed by L. Löfdahl; B. Johansson; C. Ljus; P. Ålleving


Publisher
Springer
Year
1996
Tongue
English
Weight
242 KB
Volume
20
Category
Article
ISSN
0723-4864

No coin nor oath required. For personal study only.

✦ Synopsis


A fast and simple method of determining the mean velocity vector of complex three-dimensional flow fields is outlined. Straight and slanted single hot-wires are rotated in two perpendicular planes. This method increases the angular resolution, which is of importance in flow situations where one of the velocity components dominates and the other changes rapidly from one point to another. The method was calibrated in a wind tunnel and assessed in the internal flow field at the outlet of a fan in a defroster channel. It is shown that the hot-wire method yields good agreement with corresponding flow visualizations determined using a textile thread, and an integration of the measured mean flow yields a flow rate which agrees within a few percent with corresponding direct measurements on an orifice plate.