A computerized approach to statistical quality control for radioimmunoassays in the clinical chemistry laboratory

✍ Scribed by Bernard F. McDonagh; Peter J. Munson; David Rodbard


Publisher
Elsevier Science
Year
1977
Weight
695 KB
Volume
7
Category
Article
ISSN
0010-468X

No coin nor oath required. For personal study only.

✦ Synopsis


Methods for statistical quality control for the clinical laboratory in general, and radioimmunoassay in particular, have been proposed for many years. Unfortunately, only a very small number of laboratories have adapted these procedures. By use of teletypes and other remote terminals, it is possible for all laboratories to access centralized computers where a general purpose quality control program can be stored. This relieves each laboratory of the costly task of developing software, provides some degree of inter-laboratory standardization and facilitates comparison of precision and accuracy between laboratories. A prototype program for this purpose is described. This program evaluates within-assay and between-assay variability, by means of an analysis of variance for a one-way classification random-effects model, and can monitor any assay parameter by use of control chart techniques. In addition, several tests are provided to evaluate the temporal stability of the assay system, and appropriate tests for outliers are included. Also, methods are described for combination of information from several quality control samples. This provides a valid basis for adjustment of assay results or for outright rejection of an assay. For convenience, this program is designed for output on a teletype or similar terminal located in the laboratory. Simplified versions of this program can be readily adapted to desk-top calculators. The original purpose for developing this system was to provide the clinical laboratory with a simple, general, and flexible method for assessing the performance of radioimmunoassays, but its usefulness should extend to virtually all assay methods.


πŸ“œ SIMILAR VOLUMES


Relationship of flagging frequency to co
✍ Jinsheng You; Kenneth G. Hubbard πŸ“‚ Article πŸ“… 2007 πŸ› John Wiley and Sons 🌐 English βš– 267 KB

## Abstract With the widespread use of electronic interfaces in data collection, many networks have increased, or will increase, the sampling rate and add more sensors. The associated increase in data volume will naturally lead to an increased reliance on automatic quality assurance (QA) procedures

Diagnostic DHPLC Quality Assurance (DDQA
✍ Els Schollen; Elisabeth Dequeker; Shirley McQuaid; Bruno Vankeirsbilck; GeneviΓ¨v πŸ“‚ Article πŸ“… 2005 πŸ› John Wiley and Sons 🌐 English βš– 339 KB

Genetic testing in a clinical diagnostic environment must be subject to rigorous quality control procedures, in order to ensure consistency and accuracy of results. Denaturing high performance liquid chromatography (DHPLC) has become a standard prescreening tool for mutation detection, offering very