A comparison of RIGR and SVD dynamic imaging methods

✍ Scribed by Jill M. Hanson; Zhi-Pei Liang; Richard L. Magin; Jeff L. Duerk; Paul C. Lauterbur


Publisher
John Wiley and Sons
Year
1997
Tongue
English
Weight
675 KB
Volume
38
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Several constrained imaging methods have recently been proposed for dynamic imaging applications. This paper compares two of these methods: the Reduced‐encoding Imaging by Generalized‐series Reconstruction (RIGR) and Singular Value Decomposition (SVD) methods. RIGR utilizes a priori data for optimal image reconstruction whereas the SVD method seeks to optimize data acquisition. However, this study shows that the existing SVD encoding method tends to bias the data acquisition scheme toward reproducing the known features in the reference image. This characteristic of the SVD encoding method reduces its capability to capture new image features and makes it less suitable than RIGR for dynamic imaging applications.


πŸ“œ SIMILAR VOLUMES


Comparison of statistical methods in MR
✍ Fred Godtliebsen; Emil SpjsΓΈtvoll πŸ“‚ Article πŸ“… 1991 πŸ› John Wiley and Sons 🌐 English βš– 671 KB

## Abstract The problem of recovering the true underlying scene from a noisy image is considered. Several methods are compared empirically by applying them to magnetic resonance (MR) images. It turns out that a simple method, the Gaussian window filter, gives good results. This method requires only

A comparison of one-shot and recovery me
✍ Adrian P. Crawley; R. Mark Henkelman πŸ“‚ Article πŸ“… 1988 πŸ› John Wiley and Sons 🌐 English βš– 666 KB

Spin-lattice (T1) relaxation times are conventionally estimated using inversion recovery or saturation recovery sequences. Such "recovery" methods are limited in magnetic resonance imaging by the long times required to collect multiple points along the T1 relaxation curve. This problem can be overco

Theoretical Evaluation and Comparison of
✍ R. Pohmann; M. von Kienlin; A. Haase πŸ“‚ Article πŸ“… 1997 πŸ› Elsevier Science 🌐 English βš– 327 KB

## Magnetic resonance chemical shift imaging (CSI) is becoming To cope with the long experimental duration, a number the method of choice for localized NMR spectroscopic examinaof fast CSI sequences have been developed in the past years, tions, allowing simultaneous detection of NMR spectra from a

Chemical shift imaging in nuclear magnet
✍ Rumpel, Helmut ;Pope, James M. πŸ“‚ Article πŸ“… 1993 πŸ› John Wiley and Sons 🌐 English βš– 844 KB

Chemical shift imaging techniques are magnetic resonance imaging methods that separately map the spatial distribution of individual peaks or components in a complex NMR spectrum. A range of chemical shift imaging techniques based around the commonly employed spin-echo Fourier imaging sequences is cl