𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A Comparative Study of Acquisition Schemes for Diffusion Tensor Imaging Using MRI

✍ Scribed by Nikolaos G. Papadakis; Da Xing; Christopher L.-H. Huang; Laurance D. Hall; T.Adrian Carpenter


Publisher
Elsevier Science
Year
1999
Tongue
English
Weight
740 KB
Volume
137
Category
Article
ISSN
1090-7807

No coin nor oath required. For personal study only.

✦ Synopsis


This study has investigated the effects of the selection of the diffusion-weighted (DW) gradient directions on the precision of a diffusion tensor imaging (DTI) experiment. The theoretical analysis provided a quantitative framework in which the noise performance of DTI schemes could be assessed objectively and for the development of novel DTI schemes, which employ multiple DW gradient directions. This generic framework was first applied to the examination of two commonly used DTI schemes, which employed 6 DW gradient directions and hitherto were used indiscriminately under the sole condition of noncollinearity. It was then used to design and assess a novel 12-DW-gradient-direction DTI protocol, which employed the same total number of DW acquisitions as the two conventional schemes (12). This theoretical investigation was then corroborated using rigorous simulation and DTI experiments on both an isotropic phantom and a healthy human brain. Both the theoretical and the experimental analysis demonstrated that the two conventional schemes showed a significantly different noise performance and that use of the new multiple-DW-gradient-direction scheme clearly improved the precision of the DTI measurements.


📜 SIMILAR VOLUMES


Condition Number as a Measure of Noise P
✍ Stefan Skare; Maj Hedehus; Michael E Moseley; Tie-Qiang Li 📂 Article 📅 2000 🏛 Elsevier Science 🌐 English ⚖ 312 KB

Diffusion tensor mapping with MRI can noninvasively track neural connectivity and has great potential for neural scientific research and clinical applications. For each diffusion tensor imaging (DTI) data acquisition scheme, the diffusion tensor is related to the measured apparent diffusion coeffici

Early (72-Hour) detection of radiotherap
✍ Frank Peeters; Denis Rommel; Jorge Abarca-Quinones; Vincent Grégoire; Thierry Du 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 725 KB

## Abstract ## Purpose: To assess and compare the potential of various diffusion‐related magnetic resonance imaging (MRI) parameters to detect early radiotherapy (RT)‐induced changes in tumors. ## Materials and Methods: Nineteen tumors in a rat model were imaged on a clinical 3T system before an

Reduced field-of-view MRI using outer vo
✍ B.J. Wilm; J. Svensson; A. Henning; K.P. Pruessmann; P. Boesiger; S.S. Kollias 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 558 KB

## Abstract A spin‐echo single‐shot echo‐planar imaging (SS‐EPI) technique with a reduced field of view (FOV) in the phase‐encoding direction is presented that simultaneously reduces susceptibility effects and motion artifacts in diffusion‐weighted (DW) imaging (DWI) of the spinal cord at a high fi

Improving dynamic susceptibility contras
✍ Greg Zaharchuk; Roland Bammer; Matus Straka; Rexford D. Newbould; Jarrett Rosenb 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 700 KB

## Abstract ## Purpose To test whether dynamic susceptibility contrast MRI‐based CBF measurements are improved with arterial input function (AIF) partial volume (PV) and nonlinear contrast relaxivity correction, using a gold‐standard CBF method, xenon computed tomography (xeCT). ## Materials and