A colorimetric assay for measuring the lysis of a plasma clot
β Scribed by Simon J.T. Mao; Michelle A. Tucci
- Publisher
- Elsevier Science
- Year
- 1991
- Tongue
- English
- Weight
- 468 KB
- Volume
- 192
- Category
- Article
- ISSN
- 0003-2697
No coin nor oath required. For personal study only.
β¦ Synopsis
The present study describes a simple, quantitative assay for measuring the lysis of a plasma clot. The principle of the assay is based on the release of Coomassie brilliant blue R-250 dye from the clot. Thirty microliters of freshly prepared Coomassie brilliant blue R-250 (1 mg/ml) was added to 200 microliters of diluted human plasma (1:5). After mixing, 100 microliters of thrombin (2.5 NIH units/ml) were added to mediate a plasma clot. One milliliter of streptokinase (0.1 mg/ml) was used as a plasminogen activator to initiate clot lysis. During the course of lysis, 100 microliters of soluble material were transferred to microtiter wells and the absorbance at 540 nm was determined as a measure of clot lysis. This assay was used to measure clot lysis in 18 human plasma samples. The colorimetric method (X) developed in this report correlated well with that determined using a conventional 125I-fibrinogen method (Y): Y = 0.83X + 7.98 (r = 0.91).