The Dubna radioactive beam factory (DRIBs) [1] will make use of two possibilities for producing secondary beams of radioactive nuclei. During the first phase of the project (Phase I) the possibility for obtaining radioactive nuclei in fragmentation reactions of stable nuclei, accelerated by the cycl
A beam diagnostic multisensor for low energy radioactive beams
โ Scribed by Luigi Cosentino; Paolo Finocchiaro; Alfio Pappalardo
- Publisher
- Elsevier Science
- Year
- 2010
- Tongue
- English
- Weight
- 970 KB
- Volume
- 622
- Category
- Article
- ISSN
- 0168-9002
No coin nor oath required. For personal study only.
๐ SIMILAR VOLUMES
Induced radionuclides generated from the probe which is bombarded by proton beam will turn the detector into a typical external irradiation radiation source. Thus, it is beneficial for developing radiation protection to calculate the types and the activities of radionuclides. Here we applied both a
The tilted-foil technique has been tested for a few keV/amu 14 N beam. Atomic polarization on the order of a few % was clearly observed. By inserting a second foil, which is perpendicular to the beam direction, downstream of the first tilted foil, nuclear polarization approximately 1.2% was confirme