๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

97/03162 Chilled ceiling control


Book ID
104282820
Publisher
Elsevier Science
Year
1997
Weight
178 KB
Volume
38
Category
Article
ISSN
0140-6701

No coin nor oath required. For personal study only.

โœฆ Synopsis


This forms a mixture of the pre-ceramic polymer and interface materialcoated reinforcing fibres. moulding an exhaust manifold-shaped structure from the mixture by placing the mixture on at least a portion of the castahle material, and firing the structure. The manifolds produced are resistant to erosion, minor impacts, and thermal shock. 97103147 Melting mechanism of gunning mixture particles along axis of coal-oxygen flame Wang. X. and Li, H. Gangtie, 1996, 31, (S), 21-24. 56. (In Chinese) In order to study the effect of gunning distance and particle size on the melting of refractory particles, a temperature model was developed. The model is useful for selection of gunning distance and particle size for the repair of refractory brick wall in metal smelting furnaces. 97103148 Refractories for the lining of large synthetic ammonia installations Hu, B. Naihuo Cailiao, 1996, 30, (4) 234-238. (In Chinese) The refractories used in lining of large synthetic ammonia installations are discussed. The topics include the technical principle, choice of furnace type and lining refractories of large synthetic ammonia installations imported from abroad using natural gas, residual oil and coal as raw materials and the progress of home-made refractories for gasifiers and their wear mechanism.


๐Ÿ“œ SIMILAR VOLUMES


97/03163 Chilled water cassettes
๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› Elsevier Science โš– 178 KB

This forms a mixture of the pre-ceramic polymer and interface materialcoated reinforcing fibres. moulding an exhaust manifold-shaped structure from the mixture by placing the mixture on at least a portion of the castahle material, and firing the structure. The manifolds produced are resistant to ero

Low-energy cooling of rooms with chilled
โœ Aydin Misirlioglu; Ulgen Gulcat ๐Ÿ“‚ Article ๐Ÿ“… 2005 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 433 KB

Energy-efficient and comfortable cooling systems have recently gained considerable attention in removal of heat loads from large office spaces and industrial buildings. Here in this paper, somewhat similar heat load removal analysis is made for rooms with not so large dimensions. The ceiling of the

Numerical simulation of closed wet cooli
โœ G. Gan; S.B. Riffat ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 274 KB

A numerical technique for evaluating the performance of a closed wet cooling tower for chilled ceiling systems is presented. The technique is based on computational ยฏow dynamics (CFD) for the two-phase ยฏow of gas and water droplets. The eulerian approach is used for the gas phase ยฏow and the lagrang