๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

96/03384 - Determination of germanium in environmental samples by electrothermal atomic absorption spectrometry and continuous flow hydride generation in dilute perchloric acid solution

โœ Scribed by N. Zhe-Ming; H. Bin


Publisher
Elsevier Science
Year
1996
Weight
159 KB
Volume
37
Category
Article
ISSN
0140-6701

No coin nor oath required. For personal study only.


๐Ÿ“œ SIMILAR VOLUMES


Determination of arsenic and selenium in
โœ Chris C.Y. Chan; Ram S. Sadana ๐Ÿ“‚ Article ๐Ÿ“… 1992 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 571 KB

Flow-injection analysis is applied to sample introduction in conjunction with automated hydride generation and AAS for the determination of As and Se in environmental samples such as soil, vegetation, waters, sediments, and industrial wastes. A large sample loop was used to provide high sensitivitie

Determination of Ultratrace Selenium and
โœ Lei Wei; Parul Gupta; Robert Hernandez; Fadia Farhat ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 194 KB

Hydride vapor generation atomic absorption spectrometry (AAS) is a preferred method for determination of hydride-forming elements such as selenium and arsenic, particularly at ultratrace concentration levels. In this applied research, the hydride vapor generator-coupled atomic fluorescence spectrosc