7-T MR—from research to clinical applications?
✍ Scribed by Ewald Moser; Freddy Stahlberg; Mark E. Ladd; Siegfried Trattnig
- Publisher
- John Wiley and Sons
- Year
- 2011
- Tongue
- English
- Weight
- 679 KB
- Volume
- 25
- Category
- Article
- ISSN
- 0952-3480
- DOI
- 10.1002/nbm.1794
No coin nor oath required. For personal study only.
✦ Synopsis
Over 20 000 MR systems are currently installed worldwide and, although the majority operate at magnetic fields of 1.5 T and below (i.e. about 70%), experience with 3‐T (in high‐field clinical diagnostic imaging and research) and 7‐T (research only) human MR scanners points to a future in functional and metabolic MR diagnostics. Complementary to previous studies, this review attempts to provide an overview of ultrahigh‐field MR research with special emphasis on emerging clinical applications at 7 T. We provide a short summary of the technical development and the current status of installed MR systems. The advantages and challenges of ultrahigh‐field MRI and MRS are discussed with special emphasis on radiofrequency inhomogeneity, relaxation times, signal‐to‐noise improvements, susceptibility effects, chemical shifts, specific absorption rate and other safety issues. In terms of applications, we focus on the topics most likely to gain significantly from 7‐T MR, i.e. brain imaging and spectroscopy and musculoskeletal imaging, but also body imaging, which is particularly challenging. Examples are given to demonstrate the advantages of susceptibility‐weighted imaging, time‐of‐flight MR angiography, high‐resolution functional MRI, ^1^H and ^31^P MRSI in the human brain, sodium and functional imaging of cartilage and the first results (and artefacts) using an eight‐channel body array, suggesting future areas of research that should be intensified in order to fully explore the potential of 7‐T MR systems for use in clinical diagnosis. Copyright © 2011 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
Initial 7T Clinical Cardiovascular MR imaging results are presented. Although there are many basic problems that have to be resolved, 7T cardiovascular MRI has high potential for advanced imaging. Clinical practice has to prove what the specific advantages are of highfield cardiovascular MR imaging.
The two basic research tools developed to measure tissue fluid pressure (wick catheter) and osmotic pressure (colloid osmometer) have undergone extensive validation and refinement over the past 20 years. Using these techniques, basic science investigations were undertaken of edema in Amazon reptiles