𝔖 Bobbio Scriptorium
✦   LIBER   ✦

3D velocity quantification in the heart: Improvements by 3D PC-SSFP

✍ Scribed by Marijn P. Rolf; Mark B.M. Hofman; Joost P.A. Kuijer; Albert C. van Rossum; Rob M. Heethaar


Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
591 KB
Volume
30
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose:

To test whether a 3D imaging sequence with phase contrast (PC) velocity encoding based on steady‐state free precession (SSFP) improves 3D velocity quantification in the heart compared to the currently available gradient echo (GE) approach.

Materials and Methods:

The 3D PC‐SSFP sequence with 1D velocity encoding was compared at the mitral valve in 12 healthy subjects with 3D PC‐GE at 1.5T. Velocity measurements, velocity‐to‐noise‐ratio efficiency (VNR~eff~), intra‐ and interobserver variability of area and velocity measurements, contrast‐to‐noise‐ratio (CNR), and artifact sensitivity were evaluated in both long‐ and short‐axis orientation.

Results:

Descending aorta mean and peak velocities correlated well (r^2^ = 0.79 and 0.93) between 3D PC‐SSFP and 3D PC‐GE. At the mitral valve, mean velocity correlation was moderate (r^2^ = 0.70 short axis, 0.56 long axis) and peak velocity showed good correlation (r^2^ = 0.94 short axis, 0.81 long axis). In some cases VNR~eff~ was higher, in others lesser, depending on slab orientation and cardiac phase. Intra‐ and interobserver variability was generally better for 3D PC‐SSFP. CNR improved significantly, especially at end systole. Artifact levels did not increase.

Conclusion:

3D SSFP velocity quantification was successfully tested in the heart. Blood‐myocardium contrast improved significantly, resulting in more reproducible velocity measurements for 3D PC‐SSFP at 1.5T. J. Magn. Reson. Imaging 2009;30:947–955. © 2009 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Volumetric motion quantification by 3D v
✍ Anja Lutz; Jan Paul; Axel Bornstedt; Gerd Ulrich Nienhaus; Patrick Etyngier; Pet 📂 Article 📅 2012 🏛 BioMed Central 🌐 English ⚖ 137 KB

It is objective to show the feasibility of volumetric velocity-encoded MRI (3D-TPM) to derive velocity based motion quantification parameters.

Vorticity-velocity formulations of the S
✍ A. Ern; J.-L. Guermond; L. Quartapelle 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 138 KB 👁 2 views

## Communicated by J. C. Nedelec This work studies the three-dimensional Stokes problem expressed in terms of vorticity and velocity variables. We make general assumptions on the regularity and the topological structure of the flow domain: the boundary is Lipschitz and possibly non-connected and t