## Abstract The purpose of this work was to develop an ECG‐triggered, segmented 3D true‐FISP (fast imaging with steady‐state precession) technique to improve the signal‐to‐noise ratio (SNR) and contrast‐to‐noise ratio (CNR) of breath‐hold coronary artery imaging. The major task was to optimize an a
3D magnetization-prepared imaging using a stack-of-rings trajectory
✍ Scribed by Holden H. Wu; Dwight G. Nishimura
- Publisher
- John Wiley and Sons
- Year
- 2010
- Tongue
- English
- Weight
- 919 KB
- Volume
- 63
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Efficient acquisition strategies for magnetization‐prepared imaging based on the three‐dimensional (3D) stack‐of‐rings k‐space trajectory are presented in this work. The 3D stack‐of‐rings can be acquired with centric ordering in all three dimensions for greater efficiency in capturing the desired contrast. In addition, the 3D stack‐of‐rings naturally supports spherical coverage in k‐space for shorter scan times while achieving isotropic spatial resolution. While non‐Cartesian trajectories generally suffer from greater sensitivity to system imperfections, the 3D stack‐of‐rings can enhance magnetization‐prepared imaging with a high degree of robustness to timing delays and off‐resonance effects. As demonstrated with phantom scans, timing errors and gradient delays only cause a bulk rotation of the 3D stack‐of‐rings reconstruction. Furthermore, each ring can be acquired with a time‐efficient retracing design to resolve field inhomogeneities and enable fat/water separation. To demonstrate its effectiveness, the 3D stack‐of‐rings are considered for the case of inversion‐recovery‐prepared structural brain imaging. Experimental results show that the 3D stack‐of‐rings can achieve higher signal‐to‐noise ratio and higher contrast‐to‐noise ratio within a shorter scan time when compared to the standard inversion‐recovery‐prepared sequence based on 3D Cartesian encoding. The design principles used for this specific case of inversion‐recovery‐prepared brain imaging can be applied to other magnetization‐prepared imaging applications. Magn Reson Med 63:1210–1218, 2010. © 2010 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract We show the feasibility of single breath‐hold volumetric imaging of the heart using a three‐dimensional (3D) segmented echo planar Imaging (EPI) pulse sequence. Fifteen healthy subjects were evaluated using three magnetization preparation schemes: (a) a driven equilibrium T2‐weighted pr
## Abstract This article describes a new method for object trajectory estimation that uses sequences of images taken from a monocular camera. The method integrates a Kalman filter to estimate the three‐dimensional (3D) parameters of the optical system and a lineal projective model to determine 3D p
Purpose: To develop and test a nonlocal means-based reconstruction algorithm for undersampled 3D dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) of tumors. ## Materials and Methods: We propose a reconstruction technique that is based on the recently proposed nonlocal means (NLM)