## Abstract The pulse sequences for hyperpolarized ^3^He lung MRI that have made the most clinical impact to date are 1) those that supply regional apparent diffusion coefficient (ADC) measurements, which provide insight into early emphysematous destruction of the alveoli in the lungs, and 2) high‐
3D hyperpolarized He-3 MRI of ventilation using a multi-echo projection acquisition
✍ Scribed by James H. Holmes; Rafael L. O'Halloran; Ethan K. Brodsky; Youngkyoo Jung; Walter F. Block; Sean B. Fain
- Publisher
- John Wiley and Sons
- Year
- 2008
- Tongue
- English
- Weight
- 867 KB
- Volume
- 59
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
A method is presented for high‐resolution 3D imaging of the whole lung using inhaled hyperpolarized (HP) He‐3 MR with multiple half‐echo radial trajectories that can accelerate imaging through undersampling. A multiple half‐echo radial trajectory can be used to reduce the level of artifact for undersampled 3D projection reconstruction (PR) imaging by increasing the amount of data acquired per unit time for HP He‐3 lung imaging. The point spread functions (PSFs) for breath‐held He‐3 MRI using multiple half‐echo trajectories were evaluated using simulations to predict the effects of T~2~* and gas diffusion on image quality. Results from PSF simulations were consistent with imaging results in volunteer studies showing improved image quality with increasing number of echoes using up to 8 half‐echoes. The 8‐half‐echo acquisition is shown to accommodate lost breath‐holds as short as 6 sec using a retrospective reconstruction at reduced resolution and also to allow reduced breath‐hold time compared with an equivalent Cartesian trajectory. Furthermore, preliminary results from a 3D dynamic inhalation‐exhalation maneuver are demonstrated using the 8‐half‐echo trajectory. Results demonstrate the first high‐resolution 3D PR imaging of ventilation and respiratory dynamics in humans using HP He‐3 MR. Magn Reson Med 59:1062–1071, 2008. © 2008 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract Images of hyperpolarized ^3^He were acquired during breath‐hold in four healthy volunteers with the use of an optimized 3D gradient‐echo sequence. The images were compared with existing 2D gradient‐echo methods. The average SNR from a 13‐mm‐thick slice in the peripheral lung was 1.4 tim
## Abstract ## Purpose To image respiratory dynamics and three‐dimensional (3D) ventilation during inhalation, breath‐hold, and exhalation for evaluation of obstructive lung disease using a single dose of hyperpolarized (HP) He‐3 during MRI. ## Materials and Methods A single 2D‐3D projections in
## Abstract Several radiological imaging modalities are available to assist with the clinical diagnosis of pulmonary embolism (PE). The most frequently used techniques—nuclear medicine ventilation‐perfusion (VP) scan, computed tomography (CT), magnetic resonance angiography (MRA), and pulmonary ang
## Abstract The hybrid projection reconstruction (PR) imaging provides high temporal resolution through an undersampled PR acquisition for the in‐plane dimensions and Cartesian slice encoding for the through‐plane dimension. The undersampling of projection data introduces streak artifact, which may
## Abstract Hyperpolarized (HP) ^3^He magnetic resonance imaging has been recently used to produce high‐resolution images of pulmonary ventilation after methacholine (MCh) challenge in mouse models of allergic inflammation. This capability presents an opportunity to gain new insights about these mo