𝔖 Bobbio Scriptorium
✦   LIBER   ✦

3D diffusion tensor MRI with isotropic resolution using a steady-state radial acquisition

✍ Scribed by Youngkyoo Jung; Alexey A. Samsonov; Walter F. Block; Mariana Lazar; Aiming Lu; Jing Liu; Andrew L. Alexander


Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
1004 KB
Volume
29
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose

To obtain diffusion tensor images (DTI) over a large image volume rapidly with 3D isotropic spatial resolution, minimal spatial distortions, and reduced motion artifacts, a diffusion‐weighted steady‐state 3D projection (SS 3DPR) pulse sequence was developed.

Materials and Methods

A diffusion gradient was inserted in a SS 3DPR pulse sequence. The acquisition was synchronized to the cardiac cycle, linear phase errors were corrected along the readout direction, and each projection was weighted by measures of consistency with other data. A new iterative parallel imaging reconstruction method was also implemented for removing off‐resonance and undersampling artifacts simultaneously.

Results

The contrast and appearance of both the fractional anisotropy and eigenvector color maps were substantially improved after all correction techniques were applied. True 3D DTI datasets were obtained in vivo over the whole brain (240 mm field of view in all directions) with 1.87 mm isotropic spatial resolution, six diffusion encoding directions in under 19 minutes.

Conclusion

A true 3D DTI pulse sequence with high isotropic spatial resolution was developed for whole brain imaging in under 20 minutes. To minimize the effects of brain motion, a cardiac synchronized, multiecho, DW‐SSFP pulse sequence was implemented. Motion artifacts were further reduced by a combination of linear phase correction, corrupt projection detection and rejection, sampling density reweighting, and parallel imaging reconstruction. The combination of these methods greatly improved the quality of 3D DTI in the brain. J. Magn. Reson. Imaging 2009;29:1175–1184. © 2009 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


3D steady-state diffusion-weighted imagi
✍ Jennifer A. McNab; Daniel Gallichan; Karla L. Miller 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 738 KB

## Abstract While most diffusion‐weighted imaging (DWI) is acquired using single‐shot diffusion‐weighted spin‐echo echo‐planar imaging, steady‐state DWI is an alternative method with the potential to achieve higher‐resolution images with less distortion. Steady‐state DWI is, however, best suited to

Pilot study of improved lesion character
✍ Catherine J. Moran; Frederick Kelcz; Youngkyoo Jung; Ethan K. Brodsky; Sean B. F 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 634 KB

## Abstract ## Purpose To assess a 3D radial balanced steady‐state free precession (SSFP) technique that provides submillimeter isotropic resolution and inherently registered fat and water image volumes in comparison to conventional T2‐weighted RARE imaging for lesion characterization in breast ma

3D breath-held cardiac function with pro
✍ Dana C. Peters; Daniel B. Ennis; Pratik Rohatgi; Mushabbar A. Syed; Elliot R. Mc 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 169 KB 👁 1 views

## Abstract ## Purpose To develop and validate a three‐dimensional (3D) single breath‐hold, projection reconstruction (PR), balanced steady state free precession (SSFP) method for cardiac function evaluation against a two‐dimensional (2D) multislice Fourier (Cartesian) transform (FT) SSFP method.

Advanced morphological 3D magnetic reson
✍ Goetz H. Welsch; Lukas Zak; Tallal C. Mamisch; Dominik Paul; Lars Lauer; Andreas 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 286 KB

## Abstract ## Purpose To evaluate a new isotropic 3D proton‐density, turbo‐spin‐echo sequence with variable flip‐angle distribution (PD‐SPACE) sequence compared to an isotropic 3D true‐fast‐imaging with steady‐state‐precession (True‐FISP) sequence and 2D standard MR sequences with regard to the n